The LEO5 digital manometers combine a range of functions from other KELLER manometers in a water-tight stainless steel housing. They can detect pressure peaks with a measurement interval of 5 kHz and record all measurements. Current measured values and saved data can be read out via the USB connection. The pressure values can be shown on the extra-large display in a wide range of units of pressure, which are either pre-programmed or configured by the user.
Pressure Ranges:-1…1 to 0…1000 bar
Accuracy:±0,05 %FS
Total Error Band:±0,1 %FS @ 0…50 °C
Interfaces:USB
Special characteristics:All-rounder
Display:5-digit LCD display
Reading capacity:56'000 measuring points
• Clear and unambiguous indication of measured values on TFT display
• Easy operation and parameterisation via touchscreen or via CB-Configurator Software
• Monitoring and analysis of harmonics (U, I)
• Integrated active and reactive energy meters
The BTU meter RH33 is used in applications with liquid energy carriers.It calculates the thermal energy of water acc. to EN1434, glycol/water mixtures or other fluids such as thermal oils. Temperature sensor matching using calibrated temperature sensors is done in the device.
Potential for cost savings can be shown by using the software available as an accessory.
The device has a custody transfer approval and allows bi-directional measurement, e.g. charging/discharging of a heat accumulator.
Measuring Principle:Energy manager
Function:Monitoring and billing of energy in heating and cooling applications as well as combined heating-and
Certification:CE, UL listed, CSA GP, MID 004 (custody transfer) according EN1434 (water/other liquids) and OIML R7
Input:1x Puls/Analog,; 2x RTD/Analog,; Loop power supply 24V DC (+/-16%)
Output:1x 4...20mA,; 2x digital (Open Collector)
Relay output:2x
Auxiliary power supply:Low voltage power supply: 100 bis 230 V AC (-15% / +10%); Small voltage power supply: 24 V DC (-50%
Dimensions (wxhxd):144 x 144 x 103.1 mm; (5.67" x 5.67" x 4.06")
Software:Calculated Values:; Energy, volume, density, enthalpy & enthalpy difference,; DP-Flow-Compensation,
Operation:3 button on site or via FieldCare; read out of historical / logged data via Field Data Manager Softw
Enregistrement sûr et complet et visualisation de toutes les séquences du process. Les exigences en matière de surveillance de process et d'enregistrement de données sont de plus en plus complexes. Parce que chaque valeur mesurée compte, l'enregistreur graphique Ecograph T RSG35 enregistre, visualise et surveille tous les signaux d'entrée analogiques ou numériques. Il est facile à utiliser et présente des caractéristiques permettant de réduire les coûts et simplifier l'acquisition des données.
Principe de mesure:Acquisition de données électronique
Fonctions:"Secure data recording and signal analysis Visualization Integrated web server for device set-up E-M
Entrée maximale:"12 Analog (U, I, TC, RTD, frequency, pulse) 6 Digital"
Sortie maximale:6 relais
Interface:RS232/485 (optional) Ethernet USB Modbus RTU Slave (optional) Modbus TCP Slave (optional)
Stockage / Enregistrement:Internal memory SD card USB flash drive
Affichage:TFT 5.7" colour graphic display
Boîtier:Panel desktop housing field housing
Alimentation:100…230 V AC +/-10% 24V (-10%, +15%) AC/DC
Certification:UL CSA GP
Tank Side Monitor NRF81 è un'unità per il monitoraggio e l'integrazione dei sensori per applicazioni di stoccaggio di materiali solidi. Integra diversi dati provenienti dai sensori per la misura del livello. della temperatura e della pressione in serbatoi in un sistema host di controllo. Possibilità di selezionare svariati allarmi e uscite.
Principio di misura:Livello radar
Caratteristica / Applicazione:Field gateway for tank sensor operation and monitoring and integration into inventory control system
Specialità:Hydrostatic Tank Gauging (HTG)
Alimentazione / Comunicazione:85-264VAC
Temperatura ambiente:Standard: -40°C…60°C (-40°F...140°F) For calibration to regulatory standards: -25°C…55°C (-13°F...13
Uscita:Outputs: Fieldbus: Modbus RS485. V1. HART Analog 4-20mA (Exi/Exd) Relay (Exd) Inputs: Analog 4-20mA
Certificati / Approvazioni:ATEX. FM. IEC Ex
Metrological approvals and certificates:OIML. NMi. PTB
Opzioni:Redundant fieldbus Alu-coated or 316L housing Weather protection cover mounting kit pipe
Indicazione di valori di processo/calcolati per il protocollo Fieldbus/Profibus - L'indicatore a 8 canali visualizza valori misurati, valori calcolati e informazioni di stato degli slave in una rete FOUNDATION Fieldbus™ o PROFIBUS® PA. In modalità Listener, il dispositivo rileva i vari indirizzi del bus di campo impostati e ne indica i valori. Di conseguenza, l'indicatore non incrementa il traffico lungo il bus. Con FOUNDATION Fieldbus™, i valori disponibili sul bus possono essere indicati anche mediante interconnessione dei blocchi funzione. Un campo di testo consente di visualizzare unità ingegneristica e TAG. Il trend è indicato mediante bargraph.